Accuracy |
|
DC
Ammeters and Voltmeters |
1.5% 0
to100% of full scale deflection |
|
AC
Ammeters and Voltmeters |
Moving
Iron: 1.5% 10 to100% of full scale deflection
Moving Coil: 1.5% 10 to100% of full scale deflection |
|
Frequency
Meters |
0.5%
of end scale value |
|
Input Rating |
|
DC Moving
Coil Ammeters |
50µA
to 40A DC. (Model 361: 10A max) |
|
DC Moving
Coil Voltmeters |
50mV
to 600V DC |
|
DC Moving
Coil Center Zero Ammeters |
+/-50mA to +/-40A DC. (Model 361: 10A max) |
|
DC Moving
Coil Center Zero Voltmeter |
+/-50mV to +/-600V DC. Standard 1k ohm/volt |
|
DC Moving
Coil Suppressed Zero Ammeters |
4/20mA
DC |
|
DC Moving
Coil Suppressed Zero Voltmeters |
1/5,
8/16, 16/32 or 12/24 V DC
|
|
AC Moving
Coil Ammeters |
100µA
to 750mA AC |
|
AC Moving
Coil Voltmeters |
20 to
600V AC. Standard 900ohms/volt |
|
AC Moving
Iron Ammeters |
1 to
50A AC (Model 361: non applicable) |
|
AC Moving
Iron Voltmeters |
3 to
600V AC (Model 361: non applicable) |
|
Frequency |
100/130V, 200/250V, 360/440V, 50Hz, 60Hz or 400Hz
(Model 361: non applicable) |
|
Burden |
Ammeter 0.5VA Voltmeter: 4.5VA Frequency: 4VA |
|
Overload |
1.2
continuous x 10 for 0.5 seconds |
|
Enclosure |
|
Movement |
High
torque pivot and jewel moving coil and moving iron |
|
Scale
Balance |
Within
1% of scale length |
|
Relative
Humidity |
25% to
80% nominal range of use |
|
Operating
Temperature |
-0°C
+40°C ( -32°F to + 104°F) |
|
Storage
Temperature |
-20°C
+55°C ( -4°F to + 131°F) |
|
Case and
Lower Mask |
Matt
black case UL94V. Polycarbonate cover |
|
Window |
Shatterproof polycarbonate |
|
Surface
Mounting |
4
corner studs |
|
Rear of
Panel Mounting |
2
through hole mounts (Model 361: facility pending) |
|
Compliant with |
|
Performance |
ANSI
C39.1 1981 and IEC 51 |
|
Manufacture |
UL3111-1 |
|
Scaling |
ANSI
C39.1 1981 |
|
Safety |
IEC61010-1 (LVD) and BS EN 61326:1998 (EMC) |
|
Vibration |
ANSI
C39.1 1981 cl. 5.13 |