Laureate™
DC voltage and current panel meters with a DC signal
conditioner board combine high accuracy with high read rate
and a wide range of isolated output options for computer
interface and control. Accuracy is 99.99% of full scale
±1 count.
Used as a
direct-reading DC voltmeter, the Laureate provides a
full-scale readout of ±20,000 counts and five full-scale
voltage ranges from 200.00 mV with 10 mV resolution to 660.0
V with 100 mV resolution. The 200.00 mV and 2.000 V ranges
provide a high input impedance of 1 Gohm so as to minimize
the load on the voltage signal. The maximum voltage which
can be applied on the 20, 200 and 660 Vdc ranges is 660 Vac.
Used as a DC
ammeter, the Laureate provides a full-scale readout of
±20,000 counts and four full-scale direct-reading current
ranges from 2.0000 mA with 0.1 mA resolution to 5.000 A with
1 mA resolution. The 5.000 A range measures the IR drop
across a built-in 10 mW current shunt.
PLEASE SEE TECHNICAL INFORMATION - PDF FOR COMPLETE
INFORMATION |
|
Features |
-
0.2, 2, 20, 200 and 660
V ranges.
-
2, 20, 200 mA and 5 A
ranges.
-
All ranges factory
calibrated.
-
99.99% full scale
accuracy.
-
4 1/2 digit resolution
to ±19,999 for direct readout in mV, V, mA or A.
-
1 Gohm
input impedance on 200 mV and 2 V scales.
-
Field scalable from
front panel to ±99,999 for use with external current
shunts.
-
Up to 60 conversions
per second.
-
Peak value display.
-
Selectable adaptive
digital filter.
-
Selectable fixed zero
or active least significant digit.
-
5, 10 or 24 Vdc
excitation supply.
-
External controls for
reset, meter hold and decimal points.
-
Choice of isolated
plug-in options for control and computer interface:
dual relays,
4-20 mA & 0-10 V analog output,
RS-232/485 I/O,
parallel BCD output,
low voltage AC & DC power.
-
NEMA 4X, 1/8 DIN case.
-
Certified to
UL 3101-1, CAN/CSA-C22.2, EN 61010-1 (CE Mark).
|
|
Specifications |
|
DC
Voltage |
|
DC Voltage Range |
Resolution |
Input
Ohms |
Error at 25°C
±1 count |
|
200.00 mV
2.000 V
20.000 V
200.00 V
660.0 V |
10 µV
100 µV
1 mV
10 mV
100 mV |
1 G
1 G
1 M
1 M
1 M |
0.01% FS
0.01% FS
0.01% FS
0.01% FS
0.03% FS |
|
|
DC
Current |
|
Current Range |
Resolution |
Input
Ohms |
Error at 25°C
±1 count |
|
2.0000 mA
20.000 mA
200.00 mA
5.000 A |
0.1 µA
1.0 µA
10 µA
1.0 mA |
100
10
1
0.01 |
0.01% FS
0.01% FS
0.01% FS
0.04% FS |
|
|
DC
Voltage & Current |
|
Display |
Readout Color Range
Indicators |
5 digits, 7-segment, 14.2 mm (.56")
Red or green LED
-99999 to +99999 or -99990 to +99990 (count
by 10 with rounding) Minus sign, 2 red LED lamps |
|
A-to-D Conversion |
Technique
A-to-D Rate Output Update Display Update |
Concurrent Slope™
(Pat 5,262,780)
60/s at 60 Hz, 50/s at 50 Hz 56/s at 60 Hz, 47/s at 50 Hz 3.5/s at 60 Hz, 3/s at 50 Hz |
|
Accuracy |
Span Tempco
Zero Tempco |
0.003% of reading/°C
0.1 counts/°C |
|
Noise Rejection |
CMR, DC to 60 Hz
NMR at 50/60 Hz |
130 dB
90 dB with min filtering |
|
Maximum Signal |
Max applied
voltage
Overcurrent
protection |
660 Vac for 20, 200 and 600 V ranges, 125
Vac for other
ranges
25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA,
1x for 5 A |
|
Power |
Voltage, std.
Voltage, opt. Frequency Power isolation |
85-264 Vac and 90-370 Vdc
8-28 Vac and 9-37 Vdc
DC or 49-440 Hz Safety-rated to 250 Vac, meter ground to
earth ground, DC to 60 Hz, 4.2 kVp per High Voltage Test |
|
Excitation Output |
5 Vdc
10 Vdc 24 Vdc Output isolation |
5 Vdc ±5%, 100 mA max 10 Vdc ±5%, 120 mA max
24 Vdc ±5%, 50 mA max
50 Vdc to meter ground |
|
Connector Pin Assignments |

|
|
Environmental |
Operating Temperature
Storage Temperature Relative Humidity Protection |
0°C to 55°C
-40°C to 85°C 95% at 40°C, non-condensing NEMA-4X (IP-65) when panel mounted |
|
|
|
|
|
|
. |
|