The Laureate™ load cell and microvoltmeter is a
high-sensitivity monitor and controller for use with load
cells, strain gauges and microvolt input signals where high
accuracy and stability are required.
Usage as a DC microvoltmeter provides sensitivity down to 20
mV full scale with 1 µV resolution. With a digital
multiplier of five, 99,999 counts can be displayed with a
sensitivity of 0.2 µV per count. A moving average filter
with a time constant of 1.2 sec or greater should then be
selected.
Usage as a load cell meter allows six-wire hookup and
scaling for direct readout in engineering units, such as
pounds, kilograms or PSI. Scaling can be via front panel
pushbuttons or a computer. Zero may be set from -99,999 to
+99,999. Range may be scaled from 0 to ±99,999. Digital
scaling and calibration eliminate drift caused by
potentiometers in non-microcomputer based meters.
PLEASE SEE TECHNICAL INFORMATION - PDF FOR COMPLETE
INFORMATION |
|
Features |
-
20 mV - 500
mV full-scale ranges, 4- or 6-wire connection
-
20, 50, 100, 250 & 500 mV ranges.
-
5-digit resolution with span from 0 to
± 99,999
-
Zero from -99,999 to
+99,999
-
Selectable fixed
right-hand zero.
-
Isolated 10 Vdc supply
to power up to four 350-ohm load cells in parallel.
-
4- or 6-wire hookup.
-
Ratiometric operation
to cancel variations in excitation supply.
-
Up to 60 conversions
per second.
-
Peak value display
(standard).
-
Auto-tare with tare
value stored in memory.
-
AC or DC powered.
-
Green or red display.
-
Choice of isolated
plug-in options for control and computer interface:
dual relays,
4-20 mA & 0-10 V analog output,
RS-232/485 I/O,
parallel BCD output,
low voltage AC & DC power.
-
NEMA 4X, 1/8 DIN case.
-
Certified to
UL 3101-1, CAN/CSA-C22.2, EN 61010-1 (CE Mark).
|
|
Specifications |
|
DC
Microvoltmeter Inputs |
|
Input Range
mV |
Resolution |
Error at 25°C |
|
±20.000
±50.000
±100.00
±250.00
±500.00 |
1.0 µV
2.5 µV
5.0 µV
12.5 µV
25 µV |
0.01% FS
±1 count |
|
|
Load
Cell Inputs |
|
Full-Scale
Input, mV |
Zero
Adjust |
Span
Adjust |
Error at 25°C |
|
±20.000
±50.000
±100.00
±250.00
±500.00 |
-99,999
to
+99,999 |
0 to
±99,999 |
0.01% FS
±1 count |
|
|
DC
Voltage & Current |
|
Display |
Readout Color Range
Indicators |
5 digits, 7-segment, 14.2 mm (.56")
Red or green LED
-99999 to +99999 or -99990 to +99990
(count by 10 with rounding)
Minus sign, 2 red LED lamps |
|
A-to-D Conversion |
Technique
A-to-D Rate Output Update Display Update |
Concurrent Slope™
(Pat 5,262,780)
60/s at 60 Hz, 50/s at 50 Hz
56/s at 60 Hz, 47/s at 50 Hz
3.5/s at 60 Hz, 3/s at 50 Hz |
|
Accuracy |
Span Tempco
Zero Tempco |
0.0015% of reading/°C
0.1 µV/°C |
|
Noise Rejection |
CMR, DC to 60 Hz
NMR at 50/60 Hz |
130 dB
90 dB with min filtering |
|
Power |
Voltage, std.
Voltage, opt. Frequency Power isolation |
85-264 Vac and 90-370 Vdc
8-28 Vac and 9-37 Vdc
DC or 49-440 Hz
Safety-rated to 250 Vac, meter ground to
earth ground,
DC to 60 Hz, 4.2 kVp per High Voltage Test |
|
Excitation Output |
5 Vdc
10 Vdc 24 Vdc Output isolation |
5 Vdc ±5%, 100 mA max
10 Vdc ±5%, 120 mA max
24 Vdc ±5%, 50 mA max
50 Vdc to meter ground |
|
Environmental |
Operating Temperature
Storage Temperature Relative Humidity Protection |
0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted |
|
|
|
|
|
|
. |
|